Trianglemicroworks
Don't miss out!
Thousands of developers use stack.watch to stay informed.Get an email whenever new security vulnerabilities are reported in any Trianglemicroworks product.
RSS Feeds for Trianglemicroworks security vulnerabilities
Create a CVE RSS feed including security vulnerabilities found in Trianglemicroworks products with stack.watch. Just hit watch, then grab your custom RSS feed url.
Products by Trianglemicroworks Sorted by Most Security Vulnerabilities since 2018
By the Year
In 2026 there have been 0 vulnerabilities in Trianglemicroworks. Trianglemicroworks did not have any published security vulnerabilities last year.
| Year | Vulnerabilities | Average Score |
|---|---|---|
| 2026 | 0 | 0.00 |
| 2025 | 0 | 0.00 |
| 2024 | 14 | 8.15 |
| 2023 | 2 | 7.55 |
| 2022 | 1 | 7.50 |
| 2021 | 0 | 0.00 |
| 2020 | 4 | 8.27 |
It may take a day or so for new Trianglemicroworks vulnerabilities to show up in the stats or in the list of recent security vulnerabilities. Additionally vulnerabilities may be tagged under a different product or component name.
Recent Trianglemicroworks Security Vulnerabilities
| CVE | Date | Vulnerability | Products |
|---|---|---|---|
| CVE-2024-34057 | Sep 18, 2024 |
TMW IEC 61850 Client Library before 12.2.0 Buffer OverflowTriangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service. |
|
| CVE-2022-0369 | May 07, 2024 |
Triangle MicroWorks SCADA Data Gateway RCE via Restore Workspace Directory TraversalTriangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the Restore Workspace feature. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17227. |
|
| CVE-2023-39466 | May 03, 2024 |
Triangle MicroWorks SCADA Data Gateway get_config Auth0 Info DisclosureTriangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the get_config endpoint. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20797. |
|
| CVE-2023-39457 | May 03, 2024 |
Triangle MicroWorks SCADA Data Gateway Auth Bypass (CVE-2023-39457)Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501. |
|
| CVE-2023-39458 | May 03, 2024 |
Triangle MicroWorks SCADA Data Gateway Auth Bypass via Hard-coded CertsTriangle MicroWorks SCADA Data Gateway Use of Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of certificates. The service uses a hard-coded default SSL certificate. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-20509. |
|
| CVE-2023-39459 | May 03, 2024 |
Triangle MicroWorks SCADA Data Gateway: Dir Traversal & Arbitrary File CreationTriangle MicroWorks SCADA Data Gateway Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of workspace files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to create files in the context of Administrator. Was ZDI-CAN-20531. |
|
| CVE-2023-39460 | May 03, 2024 |
TRIMicro SCADA DG Dir Traversal Arbitrary File CreationTriangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the creation of event logs. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20534. |
|
| CVE-2023-39461 | May 03, 2024 |
Triangle MicroWorks SCADA GW: Log Output Sanitization Flaw Enables File WriteTriangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability. This vulnerability allows remote attackers to write arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of event logs. The issue results from improper sanitization of log output. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20535. |
|
| CVE-2023-39462 | May 03, 2024 |
Triangle MicroWorks SCADA Data Gateway: Unrestricted File Upload (Auth Bypass)Triangle MicroWorks SCADA Data Gateway Workspace Unrestricted Upload Vulnerability. This vulnerability allows remote attackers to upload arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the processing of workspace files. The issue results from the lack of proper validation of user-supplied data, which can allow the upload of arbitrary files. An attacker can leverage this in conjunction with other vulnerabilitites to execute arbitrary code in the context of root. Was ZDI-CAN-20536. |
|
| CVE-2023-39463 | May 03, 2024 |
Triangle MicroWorks SCADA Data Gateway RCE via Untrusted Cert UploadTriangle MicroWorks SCADA Data Gateway Trusted Certification Unrestricted Upload of File Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the trusted certification feature. The issue lies in the handling of the OpcUaSecurityCertificateAuthorityTrustDir variable, which allows an arbitrary file write with attacker-controlled data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20537. |
|
| CVE-2023-39464 | May 03, 2024 |
GTWWebMonitorService Unquoted Search Path RCE on Triangle MicroWorks SCADA Data GatewayTriangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538. |
|
| CVE-2023-39465 | May 03, 2024 |
Triangle MicroWorks SCADA Data Gateway TmwCrypto Hard-Coded Crypto Key DisclosureTriangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the TmwCrypto class. The issue results from the usage of a hard-coded cryptograhic key and the usage of a hard-coded certificate. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20615. |
|
| CVE-2023-39467 | May 03, 2024 |
Triangle MicroWorks SCADA DG Cert Dir Information Disclosure (CVE-2023-39467)Triangle MicroWorks SCADA Data Gateway certificate Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of certificate web directory. The issue results from the exposure of sensitive information in the application webroot. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20798. |
|
| CVE-2023-39468 | May 03, 2024 |
RCE in Triangle MicroWorks SCADA Data Gateway via Dangerous FunctionTriangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability. The specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799. |
|
| CVE-2023-2186 | Jun 07, 2023 |
TriMicroWorks SCADA GW <=5.01.03 Format-String Leak in GWM.exeOn Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor. Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution. |
|
| CVE-2023-2187 | Jun 07, 2023 |
Unauthenticated WA Logout in Triangle MicroWorks SCADA Data Gateway v5.01.03On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event". Furthermore, an attacker could use this vulnerability to spam the logged-in user with false events. |
|
| CVE-2022-38138 | Oct 11, 2022 |
ICS DoS via Uninitialized Pointers in Triangle Microworks IEC 61850 Lib <v11.2.0The Triangle Microworks IEC 61850 Library (Any client or server using the C language library with a version number of 11.2.0 or earlier and any client or server using the C++, C#, or Java language library with a version number of 5.0.1 or earlier) and 60870-6 (ICCP/TASE.2) Library (Any client or server using a C++ language library with a version number of 4.4.3 or earlier) are vulnerable to access given to a small number of uninitialized pointers within their code. This could allow an attacker to target any client or server using the affected libraries to cause a denial-of-service condition. |
|
| CVE-2020-6996 | Apr 15, 2020 |
Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability. |
|
| CVE-2020-10615 | Apr 15, 2020 |
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability. |
|
| CVE-2020-10613 | Apr 15, 2020 |
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets. |
|
| CVE-2020-10611 | Apr 15, 2020 |
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets. |
|