Trianglemicroworks Trianglemicroworks

Don't miss out!

Thousands of developers use stack.watch to stay informed.
Get an email whenever new security vulnerabilities are reported in any Trianglemicroworks product.

RSS Feeds for Trianglemicroworks security vulnerabilities

Create a CVE RSS feed including security vulnerabilities found in Trianglemicroworks products with stack.watch. Just hit watch, then grab your custom RSS feed url.

Products by Trianglemicroworks Sorted by Most Security Vulnerabilities since 2018

By the Year

In 2026 there have been 0 vulnerabilities in Trianglemicroworks. Trianglemicroworks did not have any published security vulnerabilities last year.




Year Vulnerabilities Average Score
2026 0 0.00
2025 0 0.00
2024 14 8.15
2023 2 7.55
2022 1 7.50
2021 0 0.00
2020 4 8.27

It may take a day or so for new Trianglemicroworks vulnerabilities to show up in the stats or in the list of recent security vulnerabilities. Additionally vulnerabilities may be tagged under a different product or component name.

Recent Trianglemicroworks Security Vulnerabilities

CVE Date Vulnerability Products
CVE-2024-34057 Sep 18, 2024
TMW IEC 61850 Client Library before 12.2.0 Buffer Overflow Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service.
Iec 61850 Source Code Library
CVE-2022-0369 May 07, 2024
Triangle MicroWorks SCADA Data Gateway RCE via Restore Workspace Directory Traversal Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the Restore Workspace feature. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17227.
Scada Data Gateway
CVE-2023-39466 May 03, 2024
Triangle MicroWorks SCADA Data Gateway get_config Auth0 Info Disclosure Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the get_config endpoint. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20797.
Scada Data Gateway
CVE-2023-39457 May 03, 2024
Triangle MicroWorks SCADA Data Gateway Auth Bypass (CVE-2023-39457) Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501.
Scada Data Gateway
CVE-2023-39458 May 03, 2024
Triangle MicroWorks SCADA Data Gateway Auth Bypass via Hard-coded Certs Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of certificates. The service uses a hard-coded default SSL certificate. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-20509.
Scada Data Gateway
CVE-2023-39459 May 03, 2024
Triangle MicroWorks SCADA Data Gateway: Dir Traversal & Arbitrary File Creation Triangle MicroWorks SCADA Data Gateway Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of workspace files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to create files in the context of Administrator. Was ZDI-CAN-20531.
Scada Data Gateway
CVE-2023-39460 May 03, 2024
TRIMicro SCADA DG Dir Traversal Arbitrary File Creation Triangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the creation of event logs. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20534.
Scada Data Gateway
CVE-2023-39461 May 03, 2024
Triangle MicroWorks SCADA GW: Log Output Sanitization Flaw Enables File Write Triangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability. This vulnerability allows remote attackers to write arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of event logs. The issue results from improper sanitization of log output. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20535.
Scada Data Gateway
CVE-2023-39462 May 03, 2024
Triangle MicroWorks SCADA Data Gateway: Unrestricted File Upload (Auth Bypass) Triangle MicroWorks SCADA Data Gateway Workspace Unrestricted Upload Vulnerability. This vulnerability allows remote attackers to upload arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the processing of workspace files. The issue results from the lack of proper validation of user-supplied data, which can allow the upload of arbitrary files. An attacker can leverage this in conjunction with other vulnerabilitites to execute arbitrary code in the context of root. Was ZDI-CAN-20536.
Scada Data Gateway
CVE-2023-39463 May 03, 2024
Triangle MicroWorks SCADA Data Gateway RCE via Untrusted Cert Upload Triangle MicroWorks SCADA Data Gateway Trusted Certification Unrestricted Upload of File Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the trusted certification feature. The issue lies in the handling of the OpcUaSecurityCertificateAuthorityTrustDir variable, which allows an arbitrary file write with attacker-controlled data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20537.
Scada Data Gateway
CVE-2023-39464 May 03, 2024
GTWWebMonitorService Unquoted Search Path RCE on Triangle MicroWorks SCADA Data Gateway Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.
Scada Data Gateway
CVE-2023-39465 May 03, 2024
Triangle MicroWorks SCADA Data Gateway TmwCrypto Hard-Coded Crypto Key Disclosure Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the TmwCrypto class. The issue results from the usage of a hard-coded cryptograhic key and the usage of a hard-coded certificate. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20615.
Scada Data Gateway
CVE-2023-39467 May 03, 2024
Triangle MicroWorks SCADA DG Cert Dir Information Disclosure (CVE-2023-39467) Triangle MicroWorks SCADA Data Gateway certificate Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of certificate web directory. The issue results from the exposure of sensitive information in the application webroot. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20798.
Scada Data Gateway
CVE-2023-39468 May 03, 2024
RCE in Triangle MicroWorks SCADA Data Gateway via Dangerous Function Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability. The specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799.
Scada Data Gateway
CVE-2023-2186 Jun 07, 2023
TriMicroWorks SCADA GW <=5.01.03 Format-String Leak in GWM.exe On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor. Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution.
Scada Data Gateway
CVE-2023-2187 Jun 07, 2023
Unauthenticated WA Logout in Triangle MicroWorks SCADA Data Gateway v5.01.03 On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event". Furthermore, an attacker could use this vulnerability to spam the logged-in user with false events.
Scada Data Gateway
CVE-2022-38138 Oct 11, 2022
ICS DoS via Uninitialized Pointers in Triangle Microworks IEC 61850 Lib <v11.2.0 The Triangle Microworks IEC 61850 Library (Any client or server using the C language library with a version number of 11.2.0 or earlier and any client or server using the C++, C#, or Java language library with a version number of 5.0.1 or earlier) and 60870-6 (ICCP/TASE.2) Library (Any client or server using a C++ language library with a version number of 4.4.3 or earlier) are vulnerable to access given to a small number of uninitialized pointers within their code. This could allow an attacker to target any client or server using the affected libraries to cause a denial-of-service condition.
Iec 61850 Software Library
Iec 60870 6 Software Library
CVE-2020-6996 Apr 15, 2020
Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01 Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.
Dnp3 Source Code Library
CVE-2020-10615 Apr 15, 2020
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.
Scada Data Gateway
CVE-2020-10613 Apr 15, 2020
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
Scada Data Gateway
CVE-2020-10611 Apr 15, 2020
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
Scada Data Gateway
Built by Foundeo Inc., with data from the National Vulnerability Database (NVD). Privacy Policy. Use of this site is governed by the Legal Terms
Disclaimer
CONTENT ON THIS WEBSITE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. YOUR USE OF THE INFORMATION ON THE DOCUMENT OR MATERIALS LINKED FROM THE DOCUMENT IS AT YOUR OWN RISK. Always check with your vendor for the most up to date, and accurate information.