Modicon Premium Tsxp57 1634m Schneider Electric Modicon Premium Tsxp57 1634m

Do you want an email whenever new security vulnerabilities are reported in Schneider Electric Modicon Premium Tsxp57 1634m?

By the Year

In 2024 there have been 0 vulnerabilities in Schneider Electric Modicon Premium Tsxp57 1634m . Modicon Premium Tsxp57 1634m did not have any published security vulnerabilities last year.

Year Vulnerabilities Average Score
2024 0 0.00
2023 0 0.00
2022 0 0.00
2021 4 6.75
2020 0 0.00
2019 0 0.00
2018 0 0.00

It may take a day or so for new Modicon Premium Tsxp57 1634m vulnerabilities to show up in the stats or in the list of recent security vulnerabilties. Additionally vulnerabilities may be tagged under a different product or component name.

Recent Schneider Electric Modicon Premium Tsxp57 1634m Security Vulnerabilities

A CWE-476: NULL Pointer Dereference vulnerability

CVE-2021-22792 7.5 - High - September 02, 2021

A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions).

NULL Pointer Dereference

A CWE-787: Out-of-bounds Write vulnerability

CVE-2021-22791 6.5 - Medium - September 02, 2021

A CWE-787: Out-of-bounds Write vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions).

Memory Corruption

A CWE-125: Out-of-bounds Read vulnerability

CVE-2021-22790 6.5 - Medium - September 02, 2021

A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions).

Out-of-bounds Read

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability

CVE-2021-22789 6.5 - Medium - September 02, 2021

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions).

Buffer Overflow

Stay on top of Security Vulnerabilities

Want an email whenever new vulnerabilities are published for Schneider Electric Plc Simulator Ecostruxure Process Expert or by Schneider Electric? Click the Watch button to subscribe.

subscribe