Saia Pg5 Controls Suite Honeywell Saia Pg5 Controls Suite

Do you want an email whenever new security vulnerabilities are reported in Honeywell Saia Pg5 Controls Suite?

By the Year

In 2024 there have been 0 vulnerabilities in Honeywell Saia Pg5 Controls Suite . Saia Pg5 Controls Suite did not have any published security vulnerabilities last year.

Year Vulnerabilities Average Score
2024 0 0.00
2023 0 0.00
2022 2 6.20
2021 0 0.00
2020 0 0.00
2019 0 0.00
2018 0 0.00

It may take a day or so for new Saia Pg5 Controls Suite vulnerabilities to show up in the stats or in the list of recent security vulnerabilties. Additionally vulnerabilities may be tagged under a different product or component name.

Recent Honeywell Saia Pg5 Controls Suite Security Vulnerabilities

Saia Burgess Controls (SBC) PCD through 2022-05-06 uses a Broken or Risky Cryptographic Algorithm

CVE-2022-30320 4.3 - Medium - July 28, 2022

Saia Burgess Controls (SBC) PCD through 2022-05-06 uses a Broken or Risky Cryptographic Algorithm. According to FSCT-2022-0063, there is a Saia Burgess Controls (SBC) PCD S-Bus weak credential hashing scheme issue. The affected components are characterized as: S-Bus (5050/UDP) authentication. The potential impact is: Authentication bypass. The Saia Burgess Controls (SBC) PCD controllers utilize the S-Bus protocol (5050/UDP) for a variety of engineering purposes. It is possible to configure a password in order to restrict access to sensitive engineering functionality. Authentication is done by using the S-Bus 'write byte' message to a specific address and supplying a hashed version of the password. The hashing algorithm used is based on CRC-16 and as such not cryptographically secure. An insecure hashing algorithm is used. An attacker capable of passively observing traffic can intercept the hashed credentials and trivially find collisions allowing for authentication without having to bruteforce a keyspace defined by the actual strength of the password. This allows the attacker access to sensitive engineering functionality such as uploading/downloading control logic and manipulating controller configuration.

Use of a Broken or Risky Cryptographic Algorithm

Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass

CVE-2022-30319 8.1 - High - July 28, 2022

Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass. According to FSCT-2022-0062, there is a Saia Burgess Controls (SBC) PCD S-Bus authentication bypass issue. The affected components are characterized as: S-Bus (5050/UDP) authentication. The potential impact is: Authentication bypass. The Saia Burgess Controls (SBC) PCD controllers utilize the S-Bus protocol (5050/UDP) for a variety of engineering purposes. It is possible to configure a password in order to restrict access to sensitive engineering functionality. Authentication functions on the basis of a MAC/IP whitelist with inactivity timeout to which an authenticated client's MAC/IP is stored. UDP traffic can be spoofed to bypass the whitelist-based access control. Since UDP is stateless, an attacker capable of passively observing traffic can spoof arbitrary messages using the MAC/IP of an authenticated client. This allows the attacker access to sensitive engineering functionality such as uploading/downloading control logic and manipulating controller configuration.

Authentication Bypass by Spoofing