Industrial Edge Mgmt IEM Auth Bypass (V1.7.6-1.15.16, V2-2.1, V2.2-2.8)
CVE-2026-33892 Published on April 14, 2026

A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device. Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.

NVD

Weakness Type

Authentication Bypass by Primary Weakness

The authentication algorithm is sound, but the implemented mechanism can be bypassed as the result of a separate weakness that is primary to the authentication error.


Affected Versions

Siemens Industrial Edge Management Pro V1: Siemens Industrial Edge Management Pro V2: Siemens Industrial Edge Management Virtual:

Exploit Probability

EPSS
0.07%
Percentile
21.06%

EPSS (Exploit Prediction Scoring System) scores estimate the probability that a vulnerability will be exploited in the wild within the next 30 days. The percentile shows you how this score compares to all other vulnerabilities.