CVE-2026-24080: Memory Corruption via Malformed Params in QCOM FP TA
CVE-2026-24080 Published on August 4, 2026
Buffer Copy Without Checking Size of Input in Biometrics
Memory Corruption when handling malformed request parameters in the fingerprint TA.
Vulnerability Analysis
CVE-2026-24080 is exploitable with local system access, and requires small amount of user privileges. This vulnerability is considered to have a low attack complexity. The potential impact of an exploit of this vulnerability is considered to be very high.
Weakness Type
What is a Classic Buffer Overflow Vulnerability?
The program copies an input buffer to an output buffer without verifying that the size of the input buffer is less than the size of the output buffer, leading to a buffer overflow. A buffer overflow condition exists when a program attempts to put more data in a buffer than it can hold, or when a program attempts to put data in a memory area outside of the boundaries of a buffer. The simplest type of error, and the most common cause of buffer overflows, is the "classic" case in which the program copies the buffer without restricting how much is copied. Other variants exist, but the existence of a classic overflow strongly suggests that the programmer is not considering even the most basic of security protections.
CVE-2026-24080 has been classified to as a Classic Buffer Overflow vulnerability or weakness.
Products Associated with CVE-2026-24080
Want to know whenever a new CVE is published for Qualcomm Snapdragon? stack.watch will email you.
Affected Versions
Qualcomm, Inc. Snapdragon:- Version Cologne is affected.
- Version FastConnect 6700 is affected.
- Version FastConnect 6900 is affected.
- Version FastConnect 7800 is affected.
- Version QAM8255P is affected.
- Version QAM8295P is affected.
- Version QCA6574AU is affected.
- Version QCA6595AU is affected.
- Version QCA6678AQ is affected.
- Version QCA6696 is affected.
- Version SA6145P is affected.
- Version SA6150P is affected.
- Version SA6155P is affected.
- Version SA8145P is affected.
- Version SA8150P is affected.
- Version SA8155P is affected.
- Version SA8195P is affected.
- Version SA8255P is affected.
- Version SA8295P is affected.
- Version SA8540P is affected.
- Version SA9000P is affected.
- Version SW6100 is affected.
- Version SW6100P is affected.
- Version Themisto is affected.
- Version WCD9378C is affected.
- Version WSA8840 is affected.
- Version WSA8845 is affected.
- Version WSA8845H is affected.
- Version X2000077 is affected.
- Version X2000086 is affected.
- Version X2000090 is affected.
- Version X2000092 is affected.
- Version X2000094 is affected.
- Version XG101002 is affected.
- Version XG101032 is affected.
- Version XG101039 is affected.