IBM Power Systems Firmware BMC/FSP memory attack (FW1120.00-1060.80)
CVE-2026-16933 Published on August 19, 2026
Power System Integer Overflow
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can read and write arbitrary regions of host system memory, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.
Vulnerability Analysis
CVE-2026-16933 can be exploited with local system access, and requires user privileges. This vulnerability is considered to have a low attack complexity. The potential impact of an exploit of this vulnerability is considered to be very high.
Weakness Type
Integer Overflow or Wraparound
The software performs a calculation that can produce an integer overflow or wraparound, when the logic assumes that the resulting value will always be larger than the original value. This can introduce other weaknesses when the calculation is used for resource management or execution control. An integer overflow or wraparound occurs when an integer value is incremented to a value that is too large to store in the associated representation. When this occurs, the value may wrap to become a very small or negative number. While this may be intended behavior in circumstances that rely on wrapping, it can have security consequences if the wrap is unexpected. This is especially the case if the integer overflow can be triggered using user-supplied inputs. This becomes security-critical when the result is used to control looping, make a security decision, or determine the offset or size in behaviors such as memory allocation, copying, concatenation, etc.
Products Associated with CVE-2026-16933
Want to know whenever a new CVE is published for IBM Power Systems Firmware? stack.watch will email you.
Affected Versions
IBM Power Systems Firmware:- Version FW1120.00 is affected.
- Version FW1110.00, <= FW1110.30 is affected.
- Version FW1060.00, <= FW1060.80 is affected.
- Version FW950.00, <= FW950.H2 is affected.
- Version OP940.00, <= OP940.a1 is affected.
- Version OP940.00, <= OP940.81 is affected.