Command Injection in Mitel 6869i 4.5.0.41 Firmware Update
CVE-2024-37570 Published on June 9, 2024

On Mitel 6869i 4.5.0.41 devices, the Manual Firmware Update (upgrade.html) page does not perform sanitization on the username and path parameters (sent by an authenticated user) before appending flags to the busybox ftpget command. This leads to $() command execution.

NVD

Vulnerability Analysis

CVE-2024-37570 is exploitable with network access, and requires small amount of user privileges. This vulnerability is considered to have a low attack complexity. An automatable proof of concept (POC) exploit exists. The potential impact of an exploit of this vulnerability is considered to be very high.

Attack Vector:
NETWORK
Attack Complexity:
LOW
Privileges Required:
LOW
User Interaction:
NONE
Scope:
UNCHANGED
Confidentiality Impact:
HIGH
Integrity Impact:
HIGH
Availability Impact:
HIGH

Weakness Type

What is a Command Injection Vulnerability?

The software constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

CVE-2024-37570 has been classified to as a Command Injection vulnerability or weakness.


Products Associated with CVE-2024-37570

Want to know whenever a new CVE is published for Mitel 6869i Sip Firmware? stack.watch will email you.

 

Exploit Probability

EPSS
0.41%
Percentile
61.18%