schneider-electric interactive-graphical-scada-system-data-server CVE-2022-24313 is a vulnerability in Schneider Electric Interactive Graphical Scada System Data Server
Published on February 9, 2022

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

NVD

Weakness Type

What is a Classic Buffer Overflow Vulnerability?

The program copies an input buffer to an output buffer without verifying that the size of the input buffer is less than the size of the output buffer, leading to a buffer overflow. A buffer overflow condition exists when a program attempts to put more data in a buffer than it can hold, or when a program attempts to put data in a memory area outside of the boundaries of a buffer. The simplest type of error, and the most common cause of buffer overflows, is the "classic" case in which the program copies the buffer without restricting how much is copied. Other variants exist, but the existence of a classic overflow strongly suggests that the programmer is not considering even the most basic of security protections.

CVE-2022-24313 has been classified to as a Classic Buffer Overflow vulnerability or weakness.


Products Associated with CVE-2022-24313

Want to know whenever a new CVE is published for Schneider Electric Interactive Graphical Scada System Data Server? stack.watch will email you.

 

Exploit Probability

EPSS
7.77%
Percentile
91.88%