A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the PWD/XPWD command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)
Weakness Type
Improper Null Termination
The software does not terminate or incorrectly terminates a string or array with a null character or equivalent terminator. Null termination errors frequently occur in two different ways. An off-by-one error could cause a null to be written out of bounds, leading to an overflow. Or, a program could use a strncpy() function call incorrectly, which prevents a null terminator from being added at all. Other scenarios are possible.
Products Associated with CVE-2021-31887
Want to know whenever a new CVE is published for Siemens products? stack.watch will email you.
Affected Versions
Siemens APOGEE MBC (PPC) (BACnet):- Version All versions is affected.
- Version All versions is affected.
- Version All versions is affected.
- Version All versions is affected.
- Version All versions < V3.5.4 is affected.
- Version All versions < V2.8.19 is affected.
- Version All versions < V3.5.4 is affected.
- Version All versions < V2.8.19 is affected.
- Version All versions >= V2.3 and < V6.30.016 is affected.
- Version All versions >= V2.3 and < V6.30.016 is affected.
- Version All versions >= V2.3 and < V6.30.016 is affected.
- Version All versions >= V2.3 and < V6.30.016 is affected.
- Version All versions >= V2.3 and < V6.30.016 is affected.
- Version All versions >= V2.3 and < V6.30.016 is affected.
- Version All versions >= V2.3 and < V6.30.016 is affected.
- Version All versions >= V2.3 and < V6.30.016 is affected.
- Version All versions >= V2.3 and < V6.30.016 is affected.
- Version All versions >= V2.3 and < V6.30.016 is affected.
- Version All versions >= V2.3 and < V6.30.016 is affected.
- Version All versions >= V2.3 and < V6.30.016 is affected.
- Version All versions >= V2.3 and < V6.30.016 is affected.
- Version All versions is affected.
- Version All versions < V2017.02.4 is affected.
- Version All versions is affected.
- Version All versions < V3.5.4 is affected.
- Version All versions < V3.5.4 is affected.
Exploit Probability
EPSS (Exploit Prediction Scoring System) scores estimate the probability that a vulnerability will be exploited in the wild within the next 30 days. The percentile shows you how this score compares to all other vulnerabilities.