siemens simatic-wincc-runtime-advanced CVE-2021-27383 is a vulnerability in Siemens Simatic Wincc Runtime Advanced
Published on May 12, 2021

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.

NVD

Weakness Type

Allocation of Resources Without Limits or Throttling

The software allocates a reusable resource or group of resources on behalf of an actor without imposing any restrictions on the size or number of resources that can be allocated, in violation of the intended security policy for that actor.


Products Associated with CVE-2021-27383

You can be notified by email with stack.watch whenever vulnerabilities like CVE-2021-27383 are published in Siemens Simatic Wincc Runtime Advanced:

 

Affected Versions

Siemens SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants): Siemens SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants): Siemens SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants): Siemens SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants): Siemens SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F: Siemens SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F: Siemens SIMATIC WinCC Runtime Advanced V15: Siemens SIMATIC WinCC Runtime Advanced V16: Siemens SINAMICS GH150: Siemens SINAMICS GL150 (with option X30): Siemens SINAMICS GM150 (with option X30): Siemens SINAMICS SH150: Siemens SINAMICS SL150: Siemens SINAMICS SM120: Siemens SINAMICS SM150: Siemens SINAMICS SM150i:

Exploit Probability

EPSS
0.44%
Percentile
62.59%

EPSS (Exploit Prediction Scoring System) scores estimate the probability that a vulnerability will be exploited in the wild within the next 30 days. The percentile shows you how this score compares to all other vulnerabilities.