product logo product logo
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus.

NVD

Weakness Type

What is a Classic Buffer Overflow Vulnerability?

The program copies an input buffer to an output buffer without verifying that the size of the input buffer is less than the size of the output buffer, leading to a buffer overflow. A buffer overflow condition exists when a program attempts to put more data in a buffer than it can hold, or when a program attempts to put data in a memory area outside of the boundaries of a buffer. The simplest type of error, and the most common cause of buffer overflows, is the "classic" case in which the program copies the buffer without restricting how much is copied. Other variants exist, but the existence of a classic overflow strongly suggests that the programmer is not considering even the most basic of security protections.

CVE-2020-7559 has been classified to as a Classic Buffer Overflow vulnerability or weakness.


Products Associated with CVE-2020-7559

You can be notified by email with stack.watch whenever vulnerabilities like CVE-2020-7559 are published in these products:

 
 

Exploit Probability

EPSS
0.51%