siemens simatic-s7-1500-software-controller CVE-2019-6575 vulnerability in Siemens Products
Published on April 17, 2019

A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.

NVD

Weakness Type

Uncaught Exception

An exception is thrown from a function, but it is not caught. When an exception is not caught, it may cause the program to crash or expose sensitive information.


Products Associated with CVE-2019-6575

You can be notified by email with stack.watch whenever vulnerabilities like CVE-2019-6575 are published in these products:

 
 
 
 
 
 
 
 
 
 
 

Affected Versions

Siemens SIMATIC CP 443-1 OPC UA: Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants): Siemens SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants): Siemens SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants): Siemens SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F: Siemens SIMATIC IPC DiagMonitor: Siemens SIMATIC NET PC Software V13: Siemens SIMATIC NET PC Software V14: Siemens SIMATIC NET PC Software V15: Siemens SIMATIC RF188C: Siemens SIMATIC RF600R family: Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants): Siemens SIMATIC S7-1500 Software Controller: Siemens SIMATIC WinCC OA: Siemens SIMATIC WinCC Runtime Advanced: Siemens SINEC NMS: Siemens SINEMA Server: Siemens SINUMERIK OPC UA Server: Siemens TeleControl Server Basic:

Exploit Probability

EPSS
1.12%
Percentile
77.97%

EPSS (Exploit Prediction Scoring System) scores estimate the probability that a vulnerability will be exploited in the wild within the next 30 days. The percentile shows you how this score compares to all other vulnerabilities.