siemens nucleus-net CVE-2019-13939 vulnerability in Siemens Products
Published on January 16, 2020

A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions < V2.8.2), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8.2 < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8.2 < V2.8.19), Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Desigo PXC00-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC00-U (All versions >= V2.3x and < V6.00.327), Desigo PXC001-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC100-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC12-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC128-U (All versions >= V2.3x and < V6.00.327), Desigo PXC200-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC22-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC50-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC64-U (All versions >= V2.3x and < V6.00.327), Desigo PXM20-E (All versions >= V2.3 < V6.0.327), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All versions < V0.3.0.330), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value.

NVD

Weakness Type

Improper Input Validation

The product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.


Products Associated with CVE-2019-13939

Want to know whenever a new CVE is published for Siemens products? stack.watch will email you.

 
 
 
 
 
 
 
 

Affected Versions

Siemens APOGEE MEC/MBC/PXC (P2): Siemens APOGEE PXC Compact (BACnet): Siemens APOGEE PXC Compact (P2 Ethernet): Siemens APOGEE PXC Modular (BACnet): Siemens APOGEE PXC Modular (P2 Ethernet): Siemens Capital Embedded AR Classic 431-422: Siemens Capital Embedded AR Classic R20-11: Siemens Desigo PXC00-E.D: Siemens Desigo PXC00-U: Siemens Desigo PXC001-E.D: Siemens Desigo PXC100-E.D: Siemens Desigo PXC12-E.D: Siemens Desigo PXC128-U: Siemens Desigo PXC200-E.D: Siemens Desigo PXC22-E.D: Siemens Desigo PXC22.1-E.D: Siemens Desigo PXC36.1-E.D: Siemens Desigo PXC50-E.D: Siemens Desigo PXC64-U: Siemens Desigo PXM20-E: Siemens Nucleus NET: Siemens Nucleus ReadyStart V3: Siemens Nucleus Source Code: Siemens SIMOTICS CONNECT 400: Siemens TALON TC Compact (BACnet): Siemens TALON TC Modular (BACnet):

Exploit Probability

EPSS
0.35%
Percentile
56.76%