Tx9 Pro Firmware Tenda Tx9 Pro Firmware

Don't miss out!

Thousands of developers use stack.watch to stay informed.
Get an email whenever new security vulnerabilities are reported in Tenda Tx9 Pro Firmware.

By the Year

In 2026 there have been 0 vulnerabilities in Tenda Tx9 Pro Firmware. Tx9 Pro Firmware did not have any published security vulnerabilities last year.

Year Vulnerabilities Average Score
2026 0 0.00
2025 0 0.00
2024 4 8.80
2023 0 0.00
2022 1 7.50

It may take a day or so for new Tx9 Pro Firmware vulnerabilities to show up in the stats or in the list of recent security vulnerabilities. Additionally vulnerabilities may be tagged under a different product or component name.

Recent Tenda Tx9 Pro Firmware Security Vulnerabilities

Tenda TX9 22.03.02.10 stack-based buffer overflow in PowerSaveSet function
CVE-2024-4114 8.8 - High - April 24, 2024

A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Memory Corruption

Tenda TX9 22.03.02.10 /SetVirtualServerCfg Buffer Overflow (Critical)
CVE-2024-4112 8.8 - High - April 24, 2024

A vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Memory Corruption

Tenda TX9 22.03.02.10: Remote Stack-Buffer Overflow in SetSysTimeCfg
CVE-2024-4113 8.8 - High - April 24, 2024

A vulnerability classified as critical was found in Tenda TX9 22.03.02.10. This vulnerability affects the function sub_42D4DC of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261856. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Memory Corruption

Critical Stack Overflow in Tenda TX9 22.03.02.10 SetLEDCfg (sub_42BD7C)
CVE-2024-4111 8.8 - High - April 24, 2024

A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Memory Corruption

SW Overflow in Tenda TX9 Pro SetIpMacBind <= 22.03.02.10
CVE-2022-45337 7.5 - High - November 30, 2022

Tenda TX9 Pro v22.03.02.10 was discovered to contain a stack overflow via the list parameter at /goform/SetIpMacBind.

Memory Corruption

Stay on top of Security Vulnerabilities

Want an email whenever new vulnerabilities are published for Tenda Tx9 Pro Firmware or by Tenda? Click the Watch button to subscribe.

Tenda
Vendor

subscribe