By the Year
In 2026 there have been 0 vulnerabilities in Siemens Simatic. Last year, in 2025 Simatic had 3 security vulnerabilities published. Right now, Simatic is on track to have less security vulnerabilities in 2026 than it did last year.
| Year | Vulnerabilities | Average Score |
|---|---|---|
| 2026 | 0 | 0.00 |
| 2025 | 3 | 8.23 |
It may take a day or so for new Simatic vulnerabilities to show up in the stats or in the list of recent security vulnerabilities. Additionally vulnerabilities may be tagged under a different product or component name.
Recent Siemens Simatic Security Vulnerabilities
SIMATIC CP-1542SP-1 firmware <v2.4.24 remote config auth bypass
CVE-2025-40771
9.8 - Critical
- October 14, 2025
A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data.
Missing Authentication for Critical Function
SIMATIC S7-1200 CPU V1/V2 <V2.0.2 CaptureReplay Vulnerability
CVE-2011-20002
7.4 - High
- October 14, 2025
A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions < V2.0.2), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions < V2.0.2). Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This could allow an on-path attacker between the engineering software and the controller to execute any previously recorded commands at a later time (e.g. set the controller to STOP), regardless whether or not the controller had a password configured.
Authentication Bypass by Capture-replay
SIMATIC S7-1200 CPU Web Interface DoS before V2.0.3
CVE-2011-20001
7.5 - High
- October 14, 2025
A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions < V2.0.3), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions < V2.0.3). The web server interface of affected devices improperly processes incoming malformed HTTP traffic at high rate. This could allow an unauthenticated remote attacker to force the device entering the stop/defect state, thus creating a denial of service condition.
Improper Input Validation