Performancebridge Focal Point Philips Performancebridge Focal Point

Don't miss out!

Thousands of developers use stack.watch to stay informed.
Get an email whenever new security vulnerabilities are reported in Philips Performancebridge Focal Point.

By the Year

In 2026 there have been 0 vulnerabilities in Philips Performancebridge Focal Point. Performancebridge Focal Point did not have any published security vulnerabilities last year.

Year Vulnerabilities Average Score
2026 0 0.00
2025 0 0.00
2024 0 0.00
2023 0 0.00
2022 0 0.00
2021 0 0.00
2020 4 0.00

It may take a day or so for new Performancebridge Focal Point vulnerabilities to show up in the stats or in the list of recent security vulnerabilities. Additionally vulnerabilities may be tagged under a different product or component name.

Recent Philips Performancebridge Focal Point Security Vulnerabilities

In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input
CVE-2020-16220 - September 11, 2020

In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling.

Improper Validation of Syntactic Correctness of Input

In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates
CVE-2020-16216 - September 11, 2020

In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.

Improper Input Validation

In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate
CVE-2020-16228 - September 11, 2020

In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.

Improper Check for Certificate Revocation

In Patient Information Center iX (PICiX) Version B.02
CVE-2020-16222 - September 11, 2020

In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.

authentification

Stay on top of Security Vulnerabilities

Want an email whenever new vulnerabilities are published for Philips Performancebridge Focal Point or by Philips? Click the Watch button to subscribe.

Philips
Vendor

subscribe