Philips Performancebridge Focal Point
Don't miss out!
Thousands of developers use stack.watch to stay informed.Get an email whenever new security vulnerabilities are reported in Philips Performancebridge Focal Point.
By the Year
In 2026 there have been 0 vulnerabilities in Philips Performancebridge Focal Point. Performancebridge Focal Point did not have any published security vulnerabilities last year.
| Year | Vulnerabilities | Average Score |
|---|---|---|
| 2026 | 0 | 0.00 |
| 2025 | 0 | 0.00 |
| 2024 | 0 | 0.00 |
| 2023 | 0 | 0.00 |
| 2022 | 0 | 0.00 |
| 2021 | 0 | 0.00 |
| 2020 | 4 | 0.00 |
It may take a day or so for new Performancebridge Focal Point vulnerabilities to show up in the stats or in the list of recent security vulnerabilities. Additionally vulnerabilities may be tagged under a different product or component name.
Recent Philips Performancebridge Focal Point Security Vulnerabilities
In Patient Information Center iX (PICiX) Versions C.02, C.03,
PerformanceBridge Focal Point Version A.01, the product receives input
CVE-2020-16220
- September 11, 2020
In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling.
Improper Validation of Syntactic Correctness of Input
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750,
MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior,
the product receives input or data but does not validate or incorrectly
validates
CVE-2020-16216
- September 11, 2020
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.
Improper Input Validation
In Patient Information Center iX (PICiX) Versions C.02 and C.03,
PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors
MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and
prior, the software does not check or incorrectly checks the revocation
status of a certificate
CVE-2020-16228
- September 11, 2020
In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.
Improper Check for Certificate Revocation
In Patient Information Center iX (PICiX) Version B.02
CVE-2020-16222
- September 11, 2020
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
authentification